The NTI TRX Series is a premium wall-hung condensing boiler available in both heating-only and combi configurations, delivering high-efficiency space heating and optional domestic hot water from a compact stainless-steel system. Professionally installed by Bison Air across Toronto and York Region.

With up to 96% efficiency, advanced modulation, and built-in Wi-Fi connectivity, the TRX provides reliable hydronic heating performance for modern Ontario homes.


Heating or Combi in One Platform

  • Heating-only or combi models available

  • Up to 96% AFUE efficiency

  • Stainless steel XTRATECH® heat exchanger

  • Wall-mounted compact design

  • Ideal for radiant or radiator systems


Advanced Comfort & Modulation

  • Wide modulation range

  • Stable temperature control

  • Reduced cycling

  • Quiet operation

  • Multi-zone compatible


Built-In Smart Connectivity

  • Embedded Wi-Fi control

  • Remote diagnostics capability

  • Service monitoring

  • Installer access tools


Service-Friendly Design

  • Swing-down control panel

  • Quick-connect components

  • Easy maintenance access

  • No internal brazing joints


Flexible Installation Advantages

  • 2″ vent up to 100 ft

  • 3″ vent up to 150 ft

  • Wall-hung space saving

  • Natural gas or propane

  • Retrofit friendly


Included Professional Installation – GTA

Installation by licensed hydronic technicians serving:

Toronto • Markham • Richmond Hill • Aurora • Newmarket • Vaughan • GTA

Standard installation includes:

  • Boiler supply & mounting

  • Heating system connection

  • (Combi) domestic water connection

  • Gas & vent connection

  • Condensate drain

  • Control wiring

  • System commissioning


Warranty

  • Heat exchanger: manufacturer warranty

  • Parts: 5 years

  • Labour: 1 year
    Optional 10-year labour warranty available (+$700)


Choosing TRX Heat-Only vs Combi

Choose Heat-Only if:

  • You have indirect tank

  • Large DHW demand

  • Hydronic heating focus

Choose Combi if:

  • Want heating + hot water

  • Space saving priority

  • Moderate DHW demand

    Specifications

    MODEL TRX085 TRX120 TRX110C TRX150C TRX150
    TRX199
    TRX199C
    Space Heating
    Minimum / Maximum Input (Btu/Hr)
    9,400 / 85,000 13,200 / 120,000 11,200 / 106,000 13,200 / 120,000 15,000 / 150,000 NG19,700 / 197,000

    LP 19,200 / 192,000
    NG 19,700 / 197,000

    LP 19,200 / 192,000
    Domestic Hot Water
    Minimum / Maximum Input (Btu/Hr)
    11,200 / 114,000 13,200 / 150,000
    DOE AFUE (%) 96 95 95.5 95 95 95 95
    Heating capacity 79 111 98 111 139 184 184
    Net AHRI Rating 69 97 85 97 121 160 160
    DHW Flow Rating (at 77°F rise, gpm) N/A N/A 2.7 3.5 N/A N/A 4.8
    Installation type Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing
    Weight (lbs.) 88.2 88.6 91 92.8 115 130 135
    Gas connection 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT
    CH connections 1” Male Sweat with Adapter 1” Male Sweat with Adapter 1” Male Sweat with Adapter 1” Male Sweat with Adapter 1 1/4” Male NPT 1 1/4” Male NPT 1 1/4” Male NPT
    DHW connections N/A N/A 3/4” Male Sweat with Adapter 3/4” Male Sweat with Adapter N/A N/A 3/4” Male NPT
    Flue Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent
    Minimum - Maximum Exhaust Vent Run 2” (6 - 100 feet), 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 2” (6 - 100 feet) / 3” (6 - 150 feet) 2” (6 - 100 feet)* / 3” (6 - 150 feet) 2” (6 - 100 feet)* / 3” (6 - 150 feet)
    Minimum - Maximum Intake Air Pipe Run 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet) / 3” (0 - 150 feet) 2” (0 - 100 feet)* / 3” (0 - 150 feet) 2” (0 - 100 feet)* / 3” (0 - 150 feet)
    Shipping Weight (lbs) 78 84 83 84 115 125 130
    Power Supply 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A

    TRX085
    TRX120
    TRX150
    TRX199
    TRX110C
    TRX150C
    TRX199C




    Documents: 

    : NTI-Product-Catalogue

    :  TRX Series Brochure

     


    Parts: 5 Years
    Labor: 1 Years

    Standard Installation Included for Boilers

    When you purchase a boiler from us, the price includes standard installation to ensure your new heating system is properly installed and ready to provide efficient and reliable performance. Here's what "standard installation" typically covers:

    1. Delivery of the Boiler
      Your new boiler will be safely delivered to your home.

    2. Removal of Existing Equipment
      We will disconnect and remove your old boiler if necessary.

    3. Connecting the New Boiler

      • Installation of the new boiler in the same location as the previous one.
      • Connection to existing plumbing, gas, and electrical lines.
      • Integration with the existing heating system, including radiators or baseboard heaters.
    4. Standard Venting
      Includes installation of a flue system for proper ventilation, adhering to safety codes.

    5. System Testing
      Comprehensive testing of the boiler to ensure it operates safely and efficiently.

    6. Basic Cleanup
      Disposal of the old boiler and materials, leaving your space tidy.


    Additional Costs May Apply for Non-Standard Installation

    Some situations may require work beyond standard installation. Examples include:

    • Moving the boiler to a different location.
    • Upgrading electrical or plumbing systems.
    • Installing a complex or high-efficiency venting system.
    • Adding a condensate pump or other accessories.

    Please note that the boiler cannot be sold without installation, as it requires a certified technician to carry out the installation for safety reasons.
     Therefore, we kindly request that you contact us before making a purchase. Our technicians will visit your home to provide you with a quote for the installation.

    This information is general. Contact us for proper Boiler size, talk to an advisor, or request an in-home consultation.

    or 

    Click here to fill out the form for a free consultation.

      Special Financing + Special Offers

    You have a Budget.  We have a payment plan to match it.

    Apply for financing up to $100,000. Find out if you pre-qualify in second. No obligation, no commitment and make your large purchase more affordable by applying for an easy monthly or biweekly payment plan whit Financeit. Get pre-approved in seconds!

    Pre-qualification wont affect your credit score