The FTVN is a high efficiency, wall hung boiler using a durable, vertical down-fired stainless heat exchanger. With 10:1 modulation and 96% AFU, an integrated ECM pump and DHW diverter, quick connect components, WIFI connectivity for remote monitoring and alert notifications, the FTVN is an ideal solution for your 'peace of mind', home heating needs.
Specifications
MODEL | FTVN085 | FTVN110 | FTVN150 | FTVN199 | FTVN110C | FTVN150C | FTVN199C |
---|---|---|---|---|---|---|---|
Space Heating Minimum / Maximum Input (Btu/Hr) |
8,500 / 85,000 | 11,000 / 110,000 |
15,000 / 150,000 |
19,900 / 199,000 | 11,000 / 110,000 |
15,000 / 150,000 |
19,900 / 199,000 |
Domestic Hot Water Capacity (77F Rise) in GPM |
N/A | N/A | N/A | N/A | 2.7 | 3.6 | 4.8 |
DOE AFUE (%) | 96 | 95 | 95 | 95 | 95 | 95 | 95 |
Heating Capacity | 79 | 101 | 138 | 184 | 101 | 138 | 184 |
Net AHRI Rating | 69 | 88 | 120 | 160 | 88 | 120 | 160 |
Installation type | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing |
Weight (lbs.) | 107 | 107 | 122 | 139.5 | 107 | 128.5 | 140.5 |
Gas Connection | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT |
CH Connections | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT |
DHW Connections | N/A | N/A | N/A | N/A | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT |
Flue | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent |
Minimum - Maximum Exhaust Vent Run | 2” (6 - 100 feet), 3” (6 - 150 feet) | 2” (6 - 100 feet), 3” (6 - 150 feet) | 2” (6 - 100 feet), 3” (6 - 150 feet) | 2" (6 - 100 feet)*, 3” (6 - 150 feet) | 2” (6 - 100 feet), 3” (6 - 150 feet) | 2” (6 - 100 feet), 3” (6 - 150 feet) | 2" (6 - 100 feet)*, 3” (6 - 150 feet) |
Minimum - Maximum Intake Air Pipe Run | 2” (0 - 100 feet), 3” (0 - 150 feet) | 2” (0 - 100 feet), 3” (0 - 150 feet) | 2” (0 - 100 feet), 3” (0 - 150 feet) | 2” (0 - 100 feet)*, 3” (0 - 150 feet) | 2” (0 - 100 feet), 3” (0 - 150 feet) | 2” (0 - 100 feet), 3” (0 - 150 feet) | 2” (0 - 100 feet)*, 3” (0 - 150 feet) |
Power Supply | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A |
FTVN085 |
FTVN110 |
FTVN150 |
FTVN199 |
FTVN110C |
FTVN150C |
FTVN199C |
Documents:
Parts: 5 Years
Labor: 1 Years
Standard Installation Included for Boilers
When you purchase a boiler from us, the price includes standard installation to ensure your new heating system is properly installed and ready to provide efficient and reliable performance. Here's what "standard installation" typically covers:
-
Delivery of the Boiler
Your new boiler will be safely delivered to your home. -
Removal of Existing Equipment
We will disconnect and remove your old boiler if necessary. -
Connecting the New Boiler
- Installation of the new boiler in the same location as the previous one.
- Connection to existing plumbing, gas, and electrical lines.
- Integration with the existing heating system, including radiators or baseboard heaters.
-
Standard Venting
Includes installation of a flue system for proper ventilation, adhering to safety codes. -
System Testing
Comprehensive testing of the boiler to ensure it operates safely and efficiently. -
Basic Cleanup
Disposal of the old boiler and materials, leaving your space tidy.
Additional Costs May Apply for Non-Standard Installation
Some situations may require work beyond standard installation. Examples include:
- Moving the boiler to a different location.
- Upgrading electrical or plumbing systems.
- Installing a complex or high-efficiency venting system.
- Adding a condensate pump or other accessories.
Please note that the boiler cannot be sold without installation, as it requires a certified technician to carry out the installation for safety reasons.
Therefore, we kindly request that you contact us before making a purchase. Our technicians will visit your home to provide you with a quote for the installation.
This information is general. Contact us for proper Boiler size, talk to an advisor, or request an in-home consultation.
or
Click here to fill out the form for free consultation.
You have a Budget. We have a payment plan to match it.
Apply for financing up to $100,000. Find out if you pre-qualify in second. No obligation, no commitment and make your large purchase more affordable by applying for an easy monthly or biweekly payment plan whit Financeit. Get pre-approved in seconds!