NTI FTVN Condensing Boiler (Heat Only or Combi) – Installed in GTA

$8,386.00 $9,645.00
By NTI

Size

NTI FTVN High-Efficiency Condensing Boiler – Installation Included

The NTI FTVN Series is a high-efficiency wall-hung condensing boiler available in heating-only and combi configurations, providing reliable space heating and optional domestic hot water from a compact stainless-steel system. Professionally installed by Bison Air across Toronto and York Region.

With up to 96% AFUE efficiency, integrated ECM pump, and built-in Wi-Fi connectivity, the FTVN delivers stable hydronic heating performance for Ontario homes.


Heating or Combi Flexibility

  • Heat-only or combi models available

  • Up to 96% AFUE efficiency

  • Stainless steel heat exchanger

  • Wall-mounted compact design

  • Ideal for radiant or radiator heating


Integrated Hydronic Components

  • Built-in ECM circulation pump

  • DHW diverter (combi models)

  • Quick-connect components

  • Reduced installation complexity

  • Stable temperature control


Smart Monitoring & Connectivity

  • Built-in Wi-Fi

  • Remote monitoring capability

  • Alert notifications

  • Service diagnostics


Flexible Installation Advantages

  • 2″ vent up to 100 ft

  • 3″ vent up to 150 ft

  • Wall-hung space saving

  • Natural gas or propane

  • Retrofit friendly


Included Professional Installation – GTA

Installation by licensed hydronic technicians serving:

Toronto • Markham • Richmond Hill • Aurora • Newmarket • Vaughan • GTA

Standard installation includes:

  • Boiler supply & mounting

  • Heating system connection

  • (Combi) domestic water connection

  • Gas & vent connection

  • Condensate drain

  • Control wiring

  • System commissioning


Warranty

  • Heat exchanger: manufacturer warranty

  • Parts: 5 years

  • Labour: 1 year
    Optional 10-year labour warranty available (+$700)


Choosing Heat-Only vs Combi

Heat-Only:

  • Indirect tank present

  • High hot water demand

  • Hydronic heating focus

Combi:

  • Heating + hot water in one unit

  • Space-saving install

  • Moderate DHW demand


      Specifications

      MODEL FTVN085 FTVN110 FTVN150 FTVN199 FTVN110C FTVN150C FTVN199C
      Space Heating
      Minimum / Maximum Input (Btu/Hr)
      8,500 / 85,000 11,000 /
      110,000
      15,000 /
      150,000
      19,900 / 199,000 11,000 /
      110,000
      15,000 /
      150,000
      19,900 / 199,000
      Domestic Hot Water
      Capacity (77F Rise) in GPM
      N/A N/A N/A N/A 2.7 3.6 4.8
      DOE AFUE (%) 96 95 95 95 95 95 95
      Heating Capacity 79 101 138 184 101 138 184
      Net AHRI Rating 69 88 120 160 88 120 160
      Installation type Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing Indoor, Wall Hung, Fully Condensing
      Weight (lbs.) 107 107 122 139.5 107 128.5 140.5
      Gas Connection 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT
      CH Connections 1 1/4” Male NPT 1 1/4” Male NPT 1 1/4” Male NPT 1 1/4” Male NPT 1 1/4” Male NPT 1 1/4” Male NPT 1 1/4” Male NPT
      DHW Connections N/A N/A N/A N/A 3/4” Male NPT 3/4” Male NPT 3/4” Male NPT
      Flue Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent Category IV, Sealed Combustion Direct Vent, Power Vent
      Minimum - Maximum Exhaust Vent Run 2” (6 - 100 feet), 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 2" (6 - 100 feet)*, 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 2” (6 - 100 feet), 3” (6 - 150 feet) 2" (6 - 100 feet)*, 3” (6 - 150 feet)
      Minimum - Maximum Intake Air Pipe Run 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet)*, 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet), 3” (0 - 150 feet) 2” (0 - 100 feet)*, 3” (0 - 150 feet)
      Power Supply 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A 120V, 60 Hz, less than 12A

      FTVN085
      FTVN110
      FTVN150
      FTVN199
      FTVN110C
      FTVN150C
      FTVN199C




      Documents: 

      : NTI-Product-Catalogue

      : FTVN Series Brochure

       

      Standard Installation Included for Boilers

      When you purchase a boiler from us, the price includes standard installation to ensure your new heating system is properly installed and ready to provide efficient and reliable performance. Here's what "standard installation" typically covers:

      1. Delivery of the Boiler
        Your new boiler will be safely delivered to your home.

      2. Removal of Existing Equipment
        We will disconnect and remove your old boiler if necessary.

      3. Connecting the New Boiler

        • Installation of the new boiler in the same location as the previous one.
        • Connection to existing plumbing, gas, and electrical lines.
        • Integration with the existing heating system, including radiators or baseboard heaters.
      4. Standard Venting
        Includes installation of a flue system for proper ventilation, adhering to safety codes.

      5. System Testing
        Comprehensive testing of the boiler to ensure it operates safely and efficiently.

      6. Basic Cleanup
        Disposal of the old boiler and materials, leaving your space tidy.


      Additional Costs May Apply for Non-Standard Installation

      Some situations may require work beyond standard installation. Examples include:

      • Moving the boiler to a different location.
      • Upgrading electrical or plumbing systems.
      • Installing a complex or high-efficiency venting system.
      • Adding a condensate pump or other accessories.

      Please note that the boiler cannot be sold without installation, as it requires a certified technician to carry out the installation for safety reasons.
       Therefore, we kindly request that you contact us before making a purchase. Our technicians will visit your home to provide you with a quote for the installation.

      This information is general. Contact us for proper Boiler size, talk to an advisor, or request an in-home consultation.

      or 

      Click here to fill out the form for a free consultation.

        Special Financing + Special Offers

      You have a Budget.  We have a payment plan to match it.

      Apply for financing up to $100,000. Find out if you pre-qualify in second. No obligation, no commitment and make your large purchase more affordable by applying for an easy monthly or biweekly payment plan whit Financeit. Get pre-approved in seconds!

      Pre-qualification wont affect your credit score